D 421
08/07
- Data Brochure
Mixing Reset Module 421
1 of 20 © 2007 D 421 - 08/07
tN4 Compatible
Outdoor Reset
Single On-Off Boiler
Powered Pump Outputs
Variable Speed Injection Pump
Floating Action Valve
Includes Sensors
Features:
Information
Brochure
Choose controls
to match
application
1
Application
Brochure
Design your
mechanical
applications
2
Wiring
Brochure
Wiring and
installation of
specific control
4
Job
Record
Record settings &
wiring details for
future reference
6
Data
Brochure
Control settings
and sequence of
operation
5
Rough-in
Wiring
Rough-in
wiring
instructions
3
The Mixing Reset Module 421 provides outdoor reset to a hydronic heating system in order to maximize comfort and
efficiency. The 421 can operate a single on / off boiler and a single mix water temperature. The mix output can operate a
floating action mixing valve or a variable speed injection pump.
Introduction
51
52 55 56 57
Boiler
5453
C Com Boil MixCls
Opn
58
RR
59
Com Out
60
Variable Speed
2.5 A
7.5 A
max
61 62
N
Pump
tN4
Boil Sens Sup / Ret
Off / Flushing
Powered Output
Floating Output:
24 V (ac) 8 VA
Made in Canada
Meets Class B: Canadian
ICES & FCC Part 15
Test
Mixing Reset Module 421
Item
Menu
tektra 991-02
Var. Pump: 115V (ac) 2.5 A
Relay Rating: 115V (ac) 5 A
/
Do not apply power
System P1
63 64
N
Pump
Var. Pump Fuse
T2.5 A 250 V
H7007B
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - - Data Brochure

D 42108/07- Data BrochureMixing Reset Module 4211 of 20 © 2007 D 421 - 08/07• • tN4 Compatible • • Outdoor Reset• • Single On-Off Boiler• • Powere

Página 2 - Display and DIP Switches

© 2007 D 421 - 08/07 10 of 20Zone TestIn Zone Test mode, each tN4 device is individually turned on one at a time. The control tests each zone for up t

Página 3 - Access Level

11 of 20 © 2007 D 421 - 08/07tekmarNet®4 Communication Section AtekmarNet®4 (tN4) communicates between tN4 devices (thermostats, Reset Module and Exp

Página 4 - © 2007 D 421 - 08/07 4 of 20

© 2007 D 421 - 08/07 12 of 20Terminal UnitThere is a terminal unit setting for each tN4 bus. The Terminal Unit setting is found in the Adjust menu.Hyd

Página 5 - User Interface

13 of 20 © 2007 D 421 - 08/07Terminal Unit DefaultsWhen a terminal unit is selected, the control loads default values for the mix design, mix maximum

Página 6 - Display Menus

© 2007 D 421 - 08/07 14 of 20Boiler Temperature Control Section DDifferentialAn on / off heat source must be operated with a differential in order to

Página 7 - ADJUST MENU

15 of 20 © 2007 D 421 - 08/07Boiler Enable Section EIf the 421 is one of many controls that can call for heat to a single boiler or there is a boiler

Página 8

© 2007 D 421 - 08/07 16 of 20Error MessagesLocal Errors and Device ErrorsError messages are used to indicate a problem somewhere in the system. There

Página 9 - Testing the Control

17 of 20 © 2007 D 421 - 08/07Error Message DescriptionADJUST ERRORThe control failed to read the Adjust menu settings, and reloaded the factory defaul

Página 10

© 2007 D 421 - 08/07 18 of 20Error Message DescriptionBOILER SENSOR OPEN CIRCUITDue to an open circuit, the control failed to read the boiler sensor.

Página 11 - Sequence of Operation

19 of 20 © 2007 D 421 - 08/07TroubleshootingSymptom Possible Causes Corrective ActionBoiler does not fire when there is a mix demand.Boiler contact is

Página 12 - Warm Weather Shut Down (WWSD)

© 2007 D 421 - 08/07 2 of 20Table of ContentsTable of Contents ...2Display and DIP Switches .

Página 13 - Mixing Operation Section C

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fa

Página 14 - Mix Minimum

3 of 20 © 2007 D 421 - 08/07Access LevelBoiler Sup / RetUse the Boiler Sensor Supply / Return DIP switch to select the location of the boiler sensor.

Página 15 - Pump Exercising Section G

© 2007 D 421 - 08/07 4 of 20PUMPDisplays when the mixing pump is in operation.BURNERDisplays when the burner contact is closed.LOCKDisplays when the a

Página 16 - Error Messages

5 of 20 © 2007 D 421 - 08/07User InterfaceUse the User Interface available on the Liquid Crystal Display (LCD) to setup and monitor the operation of t

Página 17 - Error Messages (1 of 2)

© 2007 D 421 - 08/07 6 of 20View Menu (1 of 1) Item Field Range Access Description-76 to 149°F(-60.0 to 65.0°C)InSAdOUTDOOR SECTION B Current outdoor

Página 18 - Error Messages (2 of 2)

7 of 20 © 2007 D 421 - 08/07Item FieldRangeAccess Description-60 to 45°F(-51.0 to 7.0°C)Default = 10°F(-12.0°C)InSAdOUTDOOR DESIGN SECTION BThe desig

Página 19 - Troubleshooting

© 2007 D 421 - 08/07 8 of 20Item FieldRangeAccess Description30 to 230 secondsDefault = 105AdMIX MOTORThe time that the actuating motor requires to op

Página 20

9 of 20 © 2007 D 421 - 08/07Item Field Range Access DescriptionInS (Installer)Ad (Advanced)InSAdACCESS LEVELThe access level that is to be used by the

Comentários a estes Manuais

Sem comentários