3 of 4 © 2005 D 337 - 06/05
DIP Switch Settings
The DIP switches are found on the right hand side of the 337.
LED Status Indicators
Cleaning the Control
The control’s exterior can be cleaned using a damp cloth. Moisten the cloth with water and wring out prior to wiping the
control. Do not use solvents or cleaning solutions.
Dual Zone Manager 337
Meets Class B: Canadian
ICES & FCC Part 15
Made in
Canada
Power Fuse: T15 A 250 V
15 A
Zone A1
Zone A2
Power
Zone Group Pump A
Zone A3
Zone B1
Zone B2
Zone B3
tN4
tektra 996-02
For product instructions, see brochure
Input Power: 115 V (ac) ±10% 60 Hz, 15.5 A
Relay Rating: 115 V (ac) 5 A
All Loads Using Input Power: 15 A
Caution! Disconnect All
Power before Opening
Limited power available, see wiring brochure
For product literature:
www.tekmarcontrols.com
Zone Group Pump B
1
23456789101112 13 14 15 16 20
H7005B
32 33 34 35 36 37 38 39 40 41 42 43
17 18 19
21 22 23 24
25
26 27
24 V (ac) Fuse: T2.5 A 250 V
28 29 30
31
On/Off
Zone Group
Pump A Delay
Zone Group
Pump A
Zone Group
Pump B Delay
Zone Group
Pump B
A1
A2
A3
B1
B2
B3
A1
A2
A3
B1
B2
B3
tN4 C C CWWRRPmp tN4 tN4 C WRtN4 C WRRtN4 C WtN4 RCWtN4
Input Power Zn Grp Zn Grp Zone A1 Zone A2 Zone A3 Zone B1 Zone B2 Zone B3
Zn Grp B B tNt Zone A1 tNt Zone A2 tNt Zone A3 tNt Zone B1 tNt Zone B2 tNt Zone B3
N
L Pmp A Pmp B
C
Vlv
C
Vlv
C
Vlv
C
Vlv
C
Vlv
C
Vlv
Supply
/signal wires 90°C min.
24 V (ac) Fuse: T2.5 A 250 V
On/Off
Zone Group
Pump A Delay
Zone Group
Pump A
Zone Group
Pump B Delay
Zone Group
Pump B
A1
A2
A3
B1
B2
B3
A1
A2
A3
B1
B2
B3
Dual Zone Manager 337
Zone A1
Zone A2
Power
Zone Group Pump A
Zone A3
Zone B1
Zone B2
Zone B3
Zone Group Pump B
Zone Group Pump
Each zone has a corresponding Zone Group Pump DIP
switch.
Zone Group Pump DIP switch set to On:
The Zone Group Pump turns on when the zone calls for
heat.
Zone Group Pump DIP switch set to Off:
The Zone Group Pump does not turn on when the zone
calls for heat.
Zone Group Pump Delay
Each zone has a corresponding Zone Group Pump Delay
DIP switch.
Note: The Zone Group Pump Delay only operates if the
Zone Group Pump DIP switch is set to On.
Zone Group Pump Delay DIP switch set to On:
The Zone Group Pump turns on 3 minutes after the zone
calls for heat
The Zone Group Pump turns off 15 seconds after the
zone stops calling for heat.
Zone Group Pump Delay DIP switch set to Off:
The Zone Group Pump turns on when the zone calls for
heat.
The Zone Group Pump turns off when the zone stops
calling for heat.
Power LED
Green:
Normal operation.
Amber:
Power is present but the fuse for the internal 24 V (ac)
transformer is blown.
Off:
No power to the Power Input of the Zone Manager.
Zone LEDs
Green:
The zone is on.
Off:
The zone is off.
Zone Group Pump LEDs
Green:
The Zone Group Pump relay is on.
Off:
The Zone Group Pump relay is off.
Nine LEDs to provide the status of the 337’s outputs.